| Erfassungsbereich: | 0–20 ppm | Auflösung: | 0,01 ppm |
|---|---|---|---|
| Sensortyp: | Elektrochemisch | Alarmtypen: | Schall + Licht + Vibrationen |
| Tragbar: | Ja | Pumpen: | Ja |
| Präzision: | ≤ ±1–5 % FS | Antwortzeit (T90): | ≤20 Sekunden |
| Wiederholbarkeit: | ≤ ± 1% | Anzeige: | LCD-Punktmatrix-Display mit Hintergrundbeleuchtung |
A fast-response, high-accuracy handheld gas detector with built-in sampling pump, designed for phosphine (PH₃) fumigation residual monitoring. Measures from 0–20ppm with 0.01ppm resolution using an electrochemical sensor. Features Ex ia IIC T4 Ga explosion-proof certification, IP66 protection, 100 hours runtime (pump off), and triple alarm (sound, light, vibration). Essential for fumigation safety in grain storage, tobacco, timber, and container inspection.
The SKY2000 series is a portable, pump-suction gas detector designed for fast response and high accuracy. With an internal sampling pump, it actively draws air for immediate analysis – ideal for spot-checking fumigated spaces. The unit is housed in high-intensity engineering plastic, making it suitable for harsh environments.
Taking phosphine (PH₃) as an example – a common fumigant for grain, tobacco, and timber – the SKY2000 detects residual concentrations from 0–20ppm with a fine 0.01ppm resolution, ensuring safe re-entry and compliance with occupational exposure limits. The detector supports span calibration and zero calibration for reliable readings, plus a one-key factory reset. Data logging is optional (up to 100,000 readings) and can be exported to a PC via USB without additional software.
Phosphine is a highly toxic, colorless, flammable gas with a distinctive odor of garlic or decaying fish. It is widely used as a fumigant to control insects and rodents in:
| Industry | Application |
|---|---|
| Grain storage | Silos, warehouses, shipping containers (wheat, corn, rice, barley) |
| Tobacco | Cured tobacco leaves and finished products |
| Timber & wood products | Wood-boring insect control |
| Food processing | Dried fruits, nuts, spices, animal feed |
| Empty cargo containers | Preventing cross-contamination |
| Museums & archives | Insect pest control in artifacts |
Even after aeration, dangerous residual PH₃ can remain in confined spaces (deep grain piles, container corners, under tarpaulins). Monitoring ensures worker safety before re-entry.
| Concentration (ppm) | Health Impact |
|---|---|
| 0.3 ppm | OSHA PEL (8-hour TWA) |
| 1.0 ppm | NIOSH recommended exposure limit (15 min ceiling) |
| 3 ppm | Immediate eye/nose irritation, headache, nausea |
| 10 ppm | Severe respiratory distress, pulmonary edema |
| 20 ppm | Life-threatening; can be fatal with short exposure |
| 200–400 ppm | Rapid unconsciousness and death (IDLH = 50 ppm) |
Key Fact: PH₃ has no cumulative effect in the body, but acute exposure can be fatal. Its odor threshold (~0.5–1 ppm) is higher than the safe exposure limit, meaning you cannot rely on smell alone – a detector is essential.
![]()
![]()
![]()
![]()
![]()
![]()
| Parameter | Value |
|---|---|
| Gas Detected | Phosphine (PH₃) – also supports CO, H₂S, O₂, LEL, and hundreds of other gases |
| Detection Principle | Electrochemical |
| Measuring Range | 0 – 20 ppm |
| Resolution | 0.01 ppm |
| Precision | ≤ ±1–5% FS (depending on gas) |
| Response Time (T90) | ≤20 seconds |
| Repeatability | ≤ ±1% |
| Zero Shift | ≤ ±1% (FS/year) |
| Linearity Error | ≤ ±1% |
| Recovery Time | ≤10 seconds |
| Display | LCD dot matrix display with backlight |
| Gas Unit | Switchable (ppm, mg/m³) |
| Operating Language | Chinese / English |
| Data Logging | Optional – 100,000 readings, export to PC via USB (no software needed) |
| Sampling Method | Built-in pump (active suction) |
| Alarm Mode | Sound (buzzer), light (flashing LED), vibration |
| Explosion-Proof Grade | Ex ia IIC T4 Ga |
| Protection Grade | IP66 |
| Operating Temperature | -20°C to +50°C |
| Operating Humidity | 0–95% RH |
| Operating Time | 100 hours (pump off) |
| Dimensions | 205 × 75 × 32 mm |
| Weight | 300 g |
The SKY2000 is the industry standard for post-fumigation safety testing:
Shenzhen YuanTe Technology Co., Ltd. (brand: Safegas) was established in 2010 and specializes in the R&D, manufacturing, and sales of gas detection equipment and integrated systems. With over 16 years of industry expertise, the company serves sectors including grain storage, fumigation, oil & gas, chemicals, environmental protection, and municipal engineering. Their product portfolio includes portable gas detectors, fixed gas transmitters, gas analyzers, control panels, and calibration accessories. All products are manufactured under ISO9001 and ISO45001 management systems, holding international certifications such as IECEx, ATEX, and EMC. With an annual production capacity of over 80,000 units, YuanTe Technology supplies gas detection solutions to customers worldwide.